top of page

How to Monitor Data Centers and Server Rooms with LAN, LTE Backup and BMS/DCIM Integration?

1 day ago
4 min read


HW group Perseus Monitoring 155 is a 19-inch rack monitoring controller designed for data centers, server rooms and critical IT infrastructure. It combines environmental sensors, digital inputs, relay outputs, water leak detection and third-party device monitoring in one system. With LAN as the primary connection and integrated LTE backup, it supports continuous remote monitoring and alarm delivery even when the primary network connection fails, provided the device remains powered.


How Does It Work?

Perseus Monitoring 155 collects, processes and evaluates information from physical sensors, equipment alarm contacts and external monitoring devices.

It provides independent monitoring of environmental conditions and infrastructure status without requiring changes to the existing BMS, DCIM or IT monitoring platform.


What can be monitored?

  • Temperature and humidity: Monitor server racks, UPS rooms, cooling systems and technical areas.

  • Water leaks: Detect water along a sensing cable installed near cooling units, pipes or under raised floors.

  • Power conditions: Monitor AC/DC voltage, current and power availability using compatible sensors or external meters.

  • Equipment status: Receive fault signals from UPS, HVAC, generators and other systems through dry contacts.

  • Rack security: Monitor door contacts and other supported security-related signals.

  • Third-party equipment: Collect data from compatible Modbus RTU meters and supported network devices.


LAN, LTE and Remote Alarm Notifications

Perseus Monitoring 155 uses Ethernet LAN as its primary communication interface.

If the LAN connection becomes unavailable, the integrated LTE modem can provide an alternative communication path for supported remote monitoring services.


Alarm notifications include:

  • Email notifications

  • SMS and phone call alerts

  • SNMP traps

  • Local relay output activation

  • Notifications through compatible SensDesk-based monitoring portals


Important: LTE backup protects communication availability, not the electrical power supply. A UPS or another suitable backup power source is required to maintain operation during a complete power outage.


Integration with Existing BMS, DCIM and NMS

System integrators can connect Perseus Monitoring 155 to existing monitoring infrastructure using standard communication interfaces.

Protocol / Interface

Typical Integration

SNMP

Network Management Systems, including PRTG

Modbus TCP

BMS, SCADA and industrial monitoring

Modbus RTU / RS-485

External meters and compatible industrial devices

MQTT

IoT platforms and data integration

XML / Open API

Custom applications and third-party software

HWg Meters API

Collecting values from compatible external LAN devices

Perseus can also perform local alarm evaluation, calculations and automation using conditions, schedules and Lua scripts.

This allows the device to activate relay outputs based on measured conditions without relying entirely on a central monitoring platform.


Recommended Hardware – Perseus Monitoring 155

Perseus Monitoring 155 is a rack-mounted environmental monitoring controller with integrated LTE connectivity.


Technical Specifications

Feature

Perseus Monitoring 155

Installation

19-inch rack, 1U

Ethernet

LAN, primary connectivity

LTE

Integrated LTE modem, backup connection

Sensor ports

8× RJ11 (1-Wire / 1W-UNI)

Digital inputs

16× DI

Relay outputs

4× DO

Water leak detection

1× WLD sensing cable zone

RS-485

1× Modbus RTU interface

External devices

Meters API, compatible network meters

Monitoring capacity

Up to 100 meters / 1,000 variables

Supported integration

SNMP, Modbus TCP, MQTT, XML / API

Local automation

Conditions, calculations, scheduling and Lua

Alarm notifications

Email, SMS, Call, SNMP Trap, Relay

Monitoring software

Standalone or compatible SensDesk portal



Perseus Monitoring 155

Typical Applications


Data Centers and Server Rooms

Monitor temperature, humidity, water leaks, rack access, power conditions and cooling equipment faults from one rack-mounted controller.


UPS and Power Infrastructure

Connect compatible power meters over Modbus RTU and monitor UPS alarm contacts through digital inputs.


HVAC and Cooling Systems

Monitor room temperatures, humidity, cooling-unit status and condensate leaks. Integrate compatible HVAC measurements using Modbus or other supported interfaces.


Telecommunication Infrastructure

Monitor network cabinets and technical installations with LAN connectivity and LTE backup for supported remote alarms.


Distributed Critical Infrastructure

Use Perseus as a local monitoring controller while forwarding measurements and alarms to a central monitoring platform.


Comparison – Which Perseus Monitoring Device Should You Choose?

Feature

Perseus 145

Perseus 150

Perseus 155

Installation

Compact enclosure

19" rack

19" rack

LAN connectivity

Yes

Yes

Yes

LTE backup

Yes

No

Yes

RJ11 sensor ports

4

8

8

Digital inputs

4

16

16

Relay outputs

2

4

4

RS-485 Modbus RTU

Yes

Yes

Yes

WLD zones

1

1

1

Local alarm logic

Yes

Yes

Yes

Typical application

Smaller remote sites

Data centers with LAN

Critical sites requiring LTE backup

Selection recommendation:

  • Perseus Monitoring 145: For smaller installations requiring LAN and LTE connectivity.

  • Perseus Monitoring 150: For rack monitoring where LAN connectivity is sufficient.

  • Perseus Monitoring 155: For data centers and critical infrastructure requiring more I/O capacity and integrated LTE backup.



Frequently Asked Questions

1. Can Perseus Monitoring 155 operate without monitoring software?

Yes. Perseus Monitoring 155 can operate as a standalone controller with local monitoring, alarm conditions and supported notifications. A compatible SensDesk portal is optional for centralized dashboards, historical reporting and multi-site monitoring.

2. What happens if the LAN connection fails?

The integrated LTE modem provides backup connectivity for supported monitoring and alarming functions. Proper LTE configuration, mobile network coverage and a suitable power supply are required.

3. Can Perseus Monitoring 155 integrate with an existing BMS or DCIM platform?

Yes. It supports standard protocols including SNMP, Modbus TCP, MQTT and XML/API. Integration depends on the capabilities and configuration of the target platform.

4. Can it monitor third-party UPS, energy meters or HVAC equipment?

Yes. Compatible equipment can be connected through RS-485 Modbus RTU or supported LAN interfaces. The available data depends on the external device's communication protocol and register or data definitions.

5. Does Perseus Monitoring 155 support water leak detection?

Yes. It includes one WLD input for connecting a compatible water leak sensing cable. The controller can detect a water leak within the monitored cable zone and trigger an alarm.

6. Can Perseus Monitoring 155 perform local automation?

Yes. The controller supports local conditions, calculations, schedules and Lua scripts. Its four relay outputs can be used for compatible alarm signalling and control applications.


Related Products and Technical Resources


Need Environmental Monitoring for Your Project?

AC-HW supplies HW group monitoring controllers, sensors and accessories for system integrators working with data centers, BMS, DCIM, industrial facilities and critical infrastructure.


We can help you select the right controller, sensor configuration, alarm strategy and integration interfaces for your project.

 
 
 

Recent Posts

See All
Water Location Detection cable

The WLD-Location Cable Type L detects flooding and determines the distance to the point where liquid is detected. When flooding occurs inside buildings or data centers, every second counts. Locating t

 
 
 

Comments


bottom of page